Análisis de flujo en un sensor de placa de orificio

Translated title of the contribution: Flow analysis through an orifice plate sensor

Aarón Almaraz-Gómez, Isaac A. Arellano-Collí, César López-López, Gabriel Plascencia, Miguel A. Barrón-Meza, David Jaramillo

Research output: Contribution to journalArticlepeer-review

Abstract

The orifice plate is a flow sensor widely used in industry. Its wide acceptance is due to several factors, including its low cost and ease of installation and maintenance. However, due to its simplicity, this type of flowmeter induces several errors and inaccuracies at the moment of actually measuring flow. To improve the accuracy of the orifice plate sensor, a numerical and experimental analysis of water flow through an orifice plate was conducted. Results show that correction factors are needed as well as changing the position of the measurement points in order to improve the efficiency of the plate meter.

Translated title of the contributionFlow analysis through an orifice plate sensor
Original languageSpanish
Pages (from-to)107-120
Number of pages14
JournalIngenieria Hidraulica en Mexico
Volume24
Issue number3
StatePublished - 2009
Externally publishedYes

Fingerprint

Dive into the research topics of 'Flow analysis through an orifice plate sensor'. Together they form a unique fingerprint.

Cite this