Abstract
This paper describes the development of an analytical method for predicting the steady-state response of an integrated pump-motor-containment. These pumps employ a canned line-start permanent-magnet motor providing synchronous operation and high load efficiencies. The steady-state performance of the pump motor is assessed under different operating conditions. A laboratory prototype machine is used to validate the model.
Original language | English |
---|---|
Article number | 6027840 |
Pages (from-to) | 4080-4083 |
Number of pages | 4 |
Journal | IEEE Transactions on Magnetics |
Volume | 47 |
Issue number | 10 |
DOIs | |
State | Published - Oct 2011 |
Externally published | Yes |
Keywords
- Line-start motor
- permanent-magnet motor
- sealless pump