N2 - We propose a leap motion controller (LMC) dimensional verification based on ISO 10360-2:2009 with a coordinated measuring machine (CMM) as the reference framework. A pointer device comprising a thin aluminum cylinder was used to simulate a human finger. This was mounted on the spindle of the CMM to mark known positions over the LMC workspace. Polynomial tendency line corrections were applied to reduce the error in the LMC and CMM framework alignment. One dimension verification results were less than 0.1 mm in the X and Z axes, whereas the Y axis produced unsuitable results. The mean error was 9.6 mm in three-dimensional (3D) verification. Our findings demonstrate the difference between manufacturer quoted accuracy (0.01 mm) to that practically obtainable when the pointer was placed in a known position. LMC needs to add tracking models and position error compensation in applications requiring high accuracy, such as industrial processes or surgical procedure simulations.
AB - We propose a leap motion controller (LMC) dimensional verification based on ISO 10360-2:2009 with a coordinated measuring machine (CMM) as the reference framework. A pointer device comprising a thin aluminum cylinder was used to simulate a human finger. This was mounted on the spindle of the CMM to mark known positions over the LMC workspace. Polynomial tendency line corrections were applied to reduce the error in the LMC and CMM framework alignment. One dimension verification results were less than 0.1 mm in the X and Z axes, whereas the Y axis produced unsuitable results. The mean error was 9.6 mm in three-dimensional (3D) verification. Our findings demonstrate the difference between manufacturer quoted accuracy (0.01 mm) to that practically obtainable when the pointer was placed in a known position. LMC needs to add tracking models and position error compensation in applications requiring high accuracy, such as industrial processes or surgical procedure simulations.
KW - Dimensional verification
KW - Error
KW - Leap motion controller
KW - Polynomial correction
KW - Uncertainty
UR - http://www.scopus.com/inward/record.url?scp=84989870440&partnerID=8YFLogxK
U2 - 10.1016/j.measurement.2016.07.017
DO - 10.1016/j.measurement.2016.07.017
M3 - Artículo
SN - 0263-2241
VL - 93
SP - 258
EP - 264
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
ER -