Flow development of xanthan solutions in capillary rheometers

J. Pérez-González, L. de Vargas, J. Tejero

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Flow experiments through capillaries with 0.2% xanthan in aqueous solution and 0.1 N NaCl brine were carried out to study the influence of the molecular conformation on the flow development at relatively low shear rates, from 20s-1 to 400s-1. Capillaries with a wide range of length-to-diameter ratios, L/D = 4.5 to 1015 were used. The apparent viscosity as a function of L/D at a constant shear rate shows a continuous decrement of the viscosity as L/D increases, until an asymptotic value is reached. The decrement in the apparent viscosity is partially explained in terms of slip. It was found that slip is a function of L/D as well as shear stress, i.e., slip develops during flow, thus inducing spatial anisotropy in the fluid until a stable state is reached. However, the substantial difference in apparent viscosity between short capillaries and capillaries longer than 300 D may be attributed to dominant elongational flow due to the contraction in the small capillaries and slip in long capillaries. The flow in a sufficiently long capillary can be divided in four regions rather than three, as is usually assumed. In the first region, which corresponds to the entry, elongational and shear flow coexist and elongational flow dominant. In the second region, end effects and slip development are coupled. In the third region the flow is fully developed and end effects are negligible. However, the fluid shows physical characteristics different from those of the fluid at rest, as a consequence of prior slip development. The fourth zone is the exit region in which the velocity rearranges due to the change of boundary conditions. The length of each region depends on the conformation of the macromolecules and shear rate. In addition, it was found that the stiffness of xanthan increases with the increase of the ionic strength. Finally, a performance of Bagley's analysis in the whole range of L/D studied showed that the use of the Bagley correction is not a reliable way to correct for end effects when the flow is not fully developed and/or in the presence of slip.

Original languageEnglish
Pages (from-to)83-93
Number of pages11
JournalRheologica Acta
Volume31
Issue number1
DOIs
StatePublished - Jan 1992
Externally publishedYes

Keywords

  • Bagley correction
  • Capillary rheometer
  • slip development
  • xanthan solutions

Fingerprint

Dive into the research topics of 'Flow development of xanthan solutions in capillary rheometers'. Together they form a unique fingerprint.

Cite this