Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies

Alma De León-Hernández, Luisa Romero-Ornelas, Roberto G. Ramírez-Chavarría, Eva Ramón-Gallegos, Celia Sánchez-Pérez

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Analyzing the electrical double layer (EDL) in electrical impedance spectroscopy (EIS) measurement at low frequencies remains a challenging task for sensing purposes. In this work, we propose two approaches to deal with the EDL in measuring impedance for particles and non-adherent cells in an electrolytic suspension. The first approach is a simple procedure to compute a normalized electrical impedance spectrum named dispersed medium index ((Formula presented.)). The second is the EIS modeling through an equivalent electric circuit based on the so-called effective capacitance ((Formula presented.)), which unifies the EDL phenomena. Firstly, as an experiment under controlled conditions, we examine polymer particles of 6, 15, and 48 μm in diameter suspended in a 0.9% sodium chloride solution. Subsequently, we used K-562 cells and leukocytes suspended in a culture medium (RPMI-1640 supplemented) for a biological assay. As the main result, the (Formula presented.) is a function of the particle concentration. In addition, it shows a tendency with the particle size; regardless, it is limited to a volume fraction of 0.03 × 10−4 to 58 × 10−4. The (Formula presented.) is not significantly different between K-562 cells and leukocytes for most concentrations. On the other hand, the (Formula presented.) exhibits high applicability to retrieve a function that describes the concentration for each particle size, the K-562 cells, and leukocytes. The (Formula presented.) also shows a tendency with the particle size without limitation within the range tested, and it allows distinction between the K-562 and leukocytes in the 25 cells/µL to 400 cells/µL range. We achieved a simple method for determining an (Formula presented.) by unifying the parameters of an equivalent electrical circuit from data obtained with a conventional potentiostat. This simple approach is affordable for characterizing the population of non-adherent cells suspended in a cell culture medium.

Original languageEnglish
Article number697
JournalBioengineering
Volume9
Issue number11
DOIs
StatePublished - Nov 2022

Keywords

  • effective capacitance
  • electrical double layer
  • equivalent circuit
  • impedance spectroscopy
  • non-adherent cell suspension

Fingerprint

Dive into the research topics of 'Effective Capacitance from Equivalent Electrical Circuit as a Tool for Monitoring Non-Adherent Cell Suspensions at Low Frequencies'. Together they form a unique fingerprint.

Cite this