Device for testing the performance of a hydrogen sensor modified from the morris prototype

Research output: Contribution to journalArticlepeer-review

Abstract

A hydrogen permeation sensor based on the Morris prototype was designed, constructed and tested in this work. The cylinder was changed from a disc shape to a parallelepiped shape to facilitate the adhesion of the Nafion membrane and to decrease the potential H leakage on the edges of the cylinder. To test the ability of the sensor to detect hydrogen permeation, a device was designed that comprised two interconnected cells operating simultaneously. This device detects the permeation of H by the sensor and the potential reduction of a passive film. The sensor was calibrated, and the calibration curve was shown to be consistent with the Nernst equation.

Original languageEnglish
Pages (from-to)618-632
Number of pages15
JournalInternational Journal of Electrochemical Science
Volume9
Issue number2
StatePublished - Feb 2014

Keywords

  • Hydrogen induced cracking
  • Hydrogen sensor
  • Passive film
  • Permeation
  • Pipeline
  • Potential reduction
  • Steel