T1 - Comparison of current control for low harmonic distortion applied to a small wind generation system with permanent magnet synchronous generator
AU - Carranza, O.
AU - Figueres, E.
AU - Garcera, G.
AU - Ortega, R.
PY - 2012
Y1 - 2012
N2 - This paper presents a comparison between of two type of current control to reduce the THDi and increase the PF in a Three-Phase Boost Rectifier driving a small wind turbine. The two types of current controls are peak current mode control and average current mode control It is used as the input stage of small wind turbines with permanent magnet synchronous generators operating at variable speed. The Boost Rectifier output is connected to an inverter which injects the energy to a distribution power grid. The operation in discontinuous conduction mode allows significantly reducing the Total Harmonic Distortion of the current in the small wind turbine. However, it is necessary to add an input filter so that the switching ripple doesn't affect the turbine. The results demonstrate that it is better the peak current mode control, because it is achieved a smaller THDi and a higher PF in all over the operating range of the generator.
AB - This paper presents a comparison between of two type of current control to reduce the THDi and increase the PF in a Three-Phase Boost Rectifier driving a small wind turbine. The two types of current controls are peak current mode control and average current mode control It is used as the input stage of small wind turbines with permanent magnet synchronous generators operating at variable speed. The Boost Rectifier output is connected to an inverter which injects the energy to a distribution power grid. The operation in discontinuous conduction mode allows significantly reducing the Total Harmonic Distortion of the current in the small wind turbine. However, it is necessary to add an input filter so that the switching ripple doesn't affect the turbine. The results demonstrate that it is better the peak current mode control, because it is achieved a smaller THDi and a higher PF in all over the operating range of the generator.
UR - http://www.scopus.com/inward/record.url?scp=84872981976&partnerID=8YFLogxK
U2 - 10.1109/IECON.2012.6389162
DO - 10.1109/IECON.2012.6389162
M3 - Contribución a la conferencia
AN - SCOPUS:84872981976
SN - 9781467324212
T3 - IECON Proceedings (Industrial Electronics Conference)
SP - 955
EP - 960
BT - Proceedings, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
T2 - 38th Annual Conference on IEEE Industrial Electronics Society, IECON 2012
Y2 - 25 October 2012 through 28 October 2012
ER -