Abstract
An analytic technique for minimizing temperature excursions (above the average) in tubular elements of a convection-type superheater system, involving placement of tubular inserts in the distributing and collecting headers, is suggested. Operational experience with such inserts in a large superheater proved that a 2. 5 to 3. 5 increase in life of parts most susceptible to thermal damage is possible.
Original language | English |
---|---|
Pages (from-to) | 59-66 |
Number of pages | 8 |
Journal | Heat transfer. Soviet research |
Volume | 17 |
Issue number | 5 |
State | Published - Sep 1985 |