A control circuit small wind turbines with low harmonic distortion and improved power factor

O. Carranza, E. Figueres, G. Garcerá, L. G. González

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

This paper presents the application of average current mode control to reduce the THDi and increase the PF in a Three-Phase Boost Rectifier driving a small wind turbine. It is used as input stage of small wind turbines with permanent magnet synchronous generators operating at variable speed. The Boost Rectifier´s output is connected to an inverter which feeds the energy to a distribution power grid. The operation in discontinuous conduction mode allows significantly reducing the Total Harmonic Distortion of the current in the small wind turbine. However, it is necessary to add an input filter so that the switching ripple doesn´t arrive to the small wind turbine. It is evaluated the convenience of the current sensors placement in the DC side of the rectifier or at the output of the generator. The results demonstrate that it is better to place the sensors in the output of the generator, because it is achieved smaller THDi and higher PF.

Original languageEnglish
Article number380
Pages (from-to)447-452
Number of pages6
JournalRenewable Energy and Power Quality Journal
Volume1
Issue number7
DOIs
StatePublished - Apr 2009
Externally publishedYes

Keywords

  • Average current control
  • Boost rectifier
  • Discontinuous conduction mode
  • Wind turbines