Neutron H*(10) estimation and measurements around 18 MV linac

Pablo Víctor Cerón Ramírez, José Antonio Irán Díaz Góngora, Lydia Concepción Paredes Gutiérrez, Teodoro Rivera Montalvo, Héctor René Vega Carrillo

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

10 Citas (Scopus)

Resumen

Thermoluminescent dosimetry, analytical techniques and Monte Carlo calculations were used to estimate the dose of neutron radiation in a treatment room with a linear electron accelerator of 18 MV. Measurements were carried out through neutron ambient dose monitors which include pairs of thermoluminescent dosimeters TLD 600 (6LiF: Mg, Ti) and TLD 700 (7LiF: Mg, Ti), which were placed inside a paraffin spheres. The measurements has allowed to use NCRP 151 equations, these expressions are useful to find relevant dosimetric quantities. In addition, photoneutrons produced by linac head were calculated through MCNPX code taking into account the geometry and composition of the linac head principal parts.

Idioma originalInglés
Páginas (desde-hasta)2-7
Número de páginas6
PublicaciónApplied Radiation and Isotopes
Volumen117
DOI
EstadoPublicada - 1 nov. 2016
Publicado de forma externa

Huella

Profundice en los temas de investigación de 'Neutron H*(10) estimation and measurements around 18 MV linac'. En conjunto forman una huella única.

Citar esto