Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients

D. Robles-Camarillo, L. Niño-De-rivera, H. Quiroz-Mercado, M. J. López-Miranda

Research output: Contribution to conferencePaper

Abstract

The present work proposes a portable electronic waveform generator for transcorneal electrical stimulation (TES). The waveform model is generated into a digital processor, and is based on a healthy eye's multi-focal electroretinogram (MFERG) response. The stimulation protocol proposed in this paper is qualitatively different from the one reported by others like Inomata et. al. [1, 2]. Results show an improvement in patient's visual acuity and increased electrical B wave response in standard electroretinogram (ERG) tests, when TES is applied in patients suffering low vision (LV) produced by central retinal artery occlusion (CRAO). © 2009 IEEE.
Original languageAmerican English
Pages196-199
Number of pages176
DOIs
StatePublished - 1 Dec 2009
Externally publishedYes
EventMidwest Symposium on Circuits and Systems -
Duration: 1 Dec 2009 → …

Conference

ConferenceMidwest Symposium on Circuits and Systems
Period1/12/09 → …

Fingerprint

electronics
test
protocol

Cite this

Robles-Camarillo, D., Niño-De-rivera, L., Quiroz-Mercado, H., & López-Miranda, M. J. (2009). Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients. 196-199. Paper presented at Midwest Symposium on Circuits and Systems, . https://doi.org/10.1109/MWSCAS.2009.5236118
Robles-Camarillo, D. ; Niño-De-rivera, L. ; Quiroz-Mercado, H. ; López-Miranda, M. J. / Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients. Paper presented at Midwest Symposium on Circuits and Systems, .176 p.
@conference{653b08fc27a846dcbc882fcf9a5346bd,
title = "Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients",
abstract = "The present work proposes a portable electronic waveform generator for transcorneal electrical stimulation (TES). The waveform model is generated into a digital processor, and is based on a healthy eye's multi-focal electroretinogram (MFERG) response. The stimulation protocol proposed in this paper is qualitatively different from the one reported by others like Inomata et. al. [1, 2]. Results show an improvement in patient's visual acuity and increased electrical B wave response in standard electroretinogram (ERG) tests, when TES is applied in patients suffering low vision (LV) produced by central retinal artery occlusion (CRAO). {\circledC} 2009 IEEE.",
author = "D. Robles-Camarillo and L. Ni{\~n}o-De-rivera and H. Quiroz-Mercado and L{\'o}pez-Miranda, {M. J.}",
year = "2009",
month = "12",
day = "1",
doi = "10.1109/MWSCAS.2009.5236118",
language = "American English",
pages = "196--199",
note = "Midwest Symposium on Circuits and Systems ; Conference date: 01-12-2009",

}

Robles-Camarillo, D, Niño-De-rivera, L, Quiroz-Mercado, H & López-Miranda, MJ 2009, 'Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients', Paper presented at Midwest Symposium on Circuits and Systems, 1/12/09 pp. 196-199. https://doi.org/10.1109/MWSCAS.2009.5236118

Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients. / Robles-Camarillo, D.; Niño-De-rivera, L.; Quiroz-Mercado, H.; López-Miranda, M. J.

2009. 196-199 Paper presented at Midwest Symposium on Circuits and Systems, .

Research output: Contribution to conferencePaper

TY - CONF

T1 - Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients

AU - Robles-Camarillo, D.

AU - Niño-De-rivera, L.

AU - Quiroz-Mercado, H.

AU - López-Miranda, M. J.

PY - 2009/12/1

Y1 - 2009/12/1

N2 - The present work proposes a portable electronic waveform generator for transcorneal electrical stimulation (TES). The waveform model is generated into a digital processor, and is based on a healthy eye's multi-focal electroretinogram (MFERG) response. The stimulation protocol proposed in this paper is qualitatively different from the one reported by others like Inomata et. al. [1, 2]. Results show an improvement in patient's visual acuity and increased electrical B wave response in standard electroretinogram (ERG) tests, when TES is applied in patients suffering low vision (LV) produced by central retinal artery occlusion (CRAO). © 2009 IEEE.

AB - The present work proposes a portable electronic waveform generator for transcorneal electrical stimulation (TES). The waveform model is generated into a digital processor, and is based on a healthy eye's multi-focal electroretinogram (MFERG) response. The stimulation protocol proposed in this paper is qualitatively different from the one reported by others like Inomata et. al. [1, 2]. Results show an improvement in patient's visual acuity and increased electrical B wave response in standard electroretinogram (ERG) tests, when TES is applied in patients suffering low vision (LV) produced by central retinal artery occlusion (CRAO). © 2009 IEEE.

UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77950683610&origin=inward

UR - https://www.scopus.com/inward/citedby.uri?partnerID=HzOxMe3b&scp=77950683610&origin=inward

U2 - 10.1109/MWSCAS.2009.5236118

DO - 10.1109/MWSCAS.2009.5236118

M3 - Paper

SP - 196

EP - 199

ER -

Robles-Camarillo D, Niño-De-rivera L, Quiroz-Mercado H, López-Miranda MJ. Portable transcorneal electrical stimulator system, applied on electrotherapy for low vision patients. 2009. Paper presented at Midwest Symposium on Circuits and Systems, . https://doi.org/10.1109/MWSCAS.2009.5236118