Online partial discharges localization system

Primo Alberto Calva Chavarria, Diana Torres Peñaloza, Carlos Ramírez Pacheco

Research output: Contribution to journalArticle

1 Scopus citations

Abstract

In this paper the design and construction of an online non-invasive noninvasive partial discharges (PD) localization system is presented; it is integrated by four equal discone antennas with a wideband of 30 MHz to 1.2 GHz and a central frequency of 615 MHz connected to a four-channel high-resolution digital oscilloscope. The obtained electromagnetic signals are processed in a personal computer using Wavelet Transform and Fast Fourier Transform (FFT) to reduce electromagnetic noise and identify the source of the PD respectively. Additionally, a spherical algorithm for spatial localization in R3 is used. High-voltage laboratory and in situ measurements are reported.
Original languageAmerican English
Pages (from-to)91-103
Number of pages80
JournalRevista Facultad de Ingenieria
StatePublished - 8 May 2013