Induced voltage unbalance on a permanent magnet motor with armature failures

J. A. Alvarez, E. Peralta, F. P. Espino

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Scopus citations

Abstract

This paper addresses the calculation of the induced voltage in the stator winding of a permanent magnet synchronous motor under armature fault conditions. The generalized harmonic analysis is used to model the motor winding and the magnetic field in the air gap produced by the permanent magnet. Simulation results of unbalanced induced voltage are illustrated and analyzed in detail.

Original languageEnglish
Title of host publication2014 IEEE International Autumn Meeting on Power, Electronics and Computing, ROPEC 2014
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781479956838
DOIs
StatePublished - 9 Feb 2014
Externally publishedYes
Event2014 IEEE International Autumn Meeting on Power, Electronics and Computing, ROPEC 2014 - Ixtapa, Mexico