Corrosion Behavior of Ti-6Al-4V alloys

C. G. Nava-Dino, C. López-Meléndez, R. G. Bautista-Margulis, M. A. Neri-Flores, J. G. Chacón-Nava, S. D. de la Torre, J. G. Gonzalez-Rodriguez, A. Martínez-Villafañe

Research output: Contribution to journalArticle

13 Scopus citations

Abstract

The alloy Ti-6Al-4V has been considered ideal for implant applications. Electrochemical tests were made to analyze their resistance and predictability to corrosion from green dust samples, SPS (Spark Plasma Sintering) samples and commercial alloying. The corrosion behavior in Ringeŕs and Hanḱs solution was evaluated by SEM (Scanning Electron Microscope). Fractal dimension were used to study corrosion behavior and corrosion predictability was observed by modeling studies. © 2012 by ESG.
Original languageAmerican English
Pages (from-to)2389-2402
Number of pages2148
JournalInternational Journal of Electrochemical Science
StatePublished - 1 Mar 2012
Externally publishedYes